﻿Dokumentation zu: RefileNative_2016_02 (C) J.Feuerstein 

Erstellt: 15.03.2016    J.Fes
LUP.....: 15.03.2016    J.Fes

--------------------------------------------------------------------------------------------------------------------------------------------------------------------
#Doc: Aktion: #Bschreibung: [#New ]
      
CLA CommandLineArguments:
-------------------------

JobManagerCmdTools.exe -Action "RefileNative_2016_02" 
 -JobRoot_DP            "xx"                                                   #Doc: Root.Verzeichniss in dem die JobDaten liegen

Examples:
:3.1232;04.03.2016;J.Fes

#Example 1: Refile overwrite source !!NO!! usage of -RfTarget*
-Action "RefileNative_2016_02" -SubAction "PartByPart" -JobRoot_DP "V:\CustomersDataL\JobManager\2016-03-14-ExampleData\NativeFile2_nRf_Test_00014_CustomerNameShort" -RfEnv_JobMgr_nRfNXcash_DP "D:\NxDataCash" -UGII_LOAD_OPTIONS_DPNE "V:\JobManager\ProgEntw\Ver03\JobManagerV3\90-DATA\CustomerNameShort_SettingsGlobal\10-JobScripts\RefileNX10Nativ\ClientScripts\startup\load_options_Native_Refile.def" -JobData1ToProcessDoPrint -JobData2ResultsDoPrint -pauseOnEnd -verbose 

#Example 2: Refile into target dir see Option: -RfTarget_DP
-Action "RefileNative_2016_02" -SubAction "PartByPart" -JobRoot_DP "V:\CustomersDataL\JobManager\2016-03-14-ExampleData\NativeFile2_nRf_Test_00014_CustomerNameShort" -RfTarget_DP "D:\NxDataRefiled" -RfEnv_JobMgr_nRfNXcash_DP "D:\NxDataCash" -UGII_LOAD_OPTIONS_DPNE "V:\JobManager\ProgEntw\Ver03\JobManagerV3\90-DATA\CustomerNameShort_SettingsGlobal\10-JobScripts\RefileNX10Nativ\ClientScripts\startup\load_options_Native_Refile.def" -JobData1ToProcessDoPrint -JobData2ResultsDoPrint -pauseOnEnd -verbose 

#Example 3: Refile into taget dir with replace root folder structure 
            see Parameter
             -RfTargetReplSource_DP 
			   - and -
             -RfTargetReplSourceWith_DP
-Action "RefileNative_2016_02" -SubAction "PartByPart" -JobRoot_DP "V:\CustomersDataL\JobManager\2016-03-14-ExampleData\NativeFile2_nRf_Test_00014_CustomerNameShort" -RfTargetReplSource_DP "D:\NxData" -RfTargetReplSourceWith_DP "D:\NxDataRefiled" -RfEnv_JobMgr_nRfNXcash_DP "D:\NxDataCash" -UGII_LOAD_OPTIONS_DPNE "V:\JobManager\ProgEntw\Ver03\JobManagerV3\90-DATA\CustomerNameShort_SettingsGlobal\10-JobScripts\RefileNX10Nativ\ClientScripts\startup\load_options_Native_Refile.def" -JobData1ToProcessDoPrint -JobData2ResultsDoPrint -pauseOnEnd -verbose


-Action "RefileNative_2016_02" -SubAction "PartByPart" -RfParam "''-regen_lw''" -JobRoot_DP "V:\CustomersDataL\JobManager\2016-03-14-ExampleData\NativeFile2_nRf_Test_00014_CustomerNameShort" -RfTargetReplSource_DP "D:\NxData" -RfTargetReplSourceWith_DP "D:\NxDataRefiled" -RfEnv_JobMgr_nRfNXcash_DP "D:\NxDataCash" -UGII_LOAD_OPTIONS_DPNE "V:\JobManager\ProgEntw\Ver03\JobManagerV3\90-DATA\CustomerNameShort_SettingsGlobal\10-JobScripts\RefileNX10Nativ\ClientScripts\startup\load_options_Native_Refile.def" -JobData1ToProcessDoPrint -JobData2ResultsDoPrint -pauseOnEnd -verbose
-Action "RefileNative_2016_02" -SubAction "PartByPart" -RfParam "''-regen_lw -convert_mcs''" -JobRoot_DP "V:\CustomersDataL\JobManager\2016-03-14-ExampleData\NativeFile2_nRf_Test_00014_CustomerNameShort" -RfTargetReplSource_DP "D:\NxData" -RfTargetReplSourceWith_DP "D:\NxDataRefiled" -RfEnv_JobMgr_nRfNXcash_DP "D:\NxDataCash" -UGII_LOAD_OPTIONS_DPNE "V:\JobManager\ProgEntw\Ver03\JobManagerV3\90-DATA\CustomerNameShort_SettingsGlobal\10-JobScripts\RefileNX10Nativ\ClientScripts\startup\load_options_Native_Refile.def" -JobData1ToProcessDoPrint -JobData2ResultsDoPrint -pauseOnEnd -verbose


#New: 3.1491;17.02.2020;J.Fes
#Exa: for Debug not working with option -managed_mode=noXX
-Action "RefileNative_2016_02" -SubAction "PartByPart" -RfParam "''-managed_mode=noXX -co -regen_lw -convert_line_widths''" -JobRoot_DP "V:\CustomersDataL\SuS\2020-02-17-ExampleData\Daten_CAD_02_NX12PartUtilNativ_SP_T_00003_CustomerNameShort" -JobTemp_DP "#JobRoot_DP#\01-JobTemp" -RfProg_DPNE "C:\Program Files\Siemens\NX12\nxbin\part_utility.exe" -ShellMaxDurationSEC "-1" -JobData1ToProcessDoPrint -JobData2ResultsDoPrint -ResultClassification_DPNE "#JobRoot_DP#\Resources\NxPartUtilNativSylog_ResClRules.xml" -Verbose -PauseOnEnd
#Exa: all Pars having Issues
-Action "RefileNative_2016_02" -SubAction "PartByPart" -RfParam "''-managed_mode=no -co -regen_lw -convert_line_widths''" -JobRoot_DP "V:\CustomersDataL\SuS\2020-02-17-ExampleData\Daten_CAD_02_NX12PartUtilNativ_SP_T_00003_CustomerNameShort" -JobTemp_DP "#JobRoot_DP#\01-JobTemp" -RfProg_DPNE "C:\Program Files\Siemens\NX12\nxbin\part_utility.exe" -ShellMaxDurationSEC "-1" -JobData1ToProcessDoPrint -JobData2ResultsDoPrint -ResultClassification_DPNE "#JobRoot_DP#\Resources\NxPartUtilNativSylog_ResClRules.xml" -Verbose -PauseOnEnd

#Exa: conver MCS
-Action "RefileNative_2016_02" -SubAction "PartByPart" -RfParam "''-managed_mode=no -co -convert_mcs -mc_dry_run -mc_parts_only -convert_line_widths''" -JobRoot_DP "V:\CustomersDataL\SuS\2020-02-17-ExampleData\Daten_CAD_02_NX12PartUtilNativ3_APmcs_M_00001_CustomerNameShort" -JobTemp_DP "#JobRoot_DP#\01-JobTemp" -RfProg_DPNE "C:\Program Files\Siemens\NX12\nxbin\part_utility.exe" -ShellMaxDurationSEC "-1" -JobData1ToProcessDoPrint -JobData2ResultsDoPrint -ResultClassification_DPNE "#JobRoot_DP#\Resources\NxPartUtilNativSylog_ResClRules.xml" -Verbose -PauseOnEnd
-Action "RefileNative_2016_02" -SubAction "PartByPart" -RfParam "''-managed_mode=no -co -convert_mcs -mc_dry_run -mc_parts_only -convert_line_widths''" -JobRoot_DP "V:\CustomersDataL\SuS\2020-02-17-ExampleData\Daten_CAD_02_NX12PartUtilNativ3_APmcs_M_00002_CustomerNameShort" -JobTemp_DP "#JobRoot_DP#\01-JobTemp" -RfProg_DPNE "C:\Program Files\Siemens\NX12\nxbin\part_utility.exe" -ShellMaxDurationSEC "-1" -JobData1ToProcessDoPrint -JobData2ResultsDoPrint -ResultClassification_DPNE "#JobRoot_DP#\Resources\NxPartUtilNativSylog_ResClRules.xml" -Verbose -PauseOnEnd -Test

-Action "RefileNative_2016_02" -SubAction "PartByPart" -RfParam "''-managed_mode=no -co -convert_line_widths -regen_lw''" -JobRoot_DP "V:\CustomersDataL\SuS\2020-02-19-ExampleData\Daten_CAD_02_NX12PartUtilNativ_SP_T_00009_CustomerNameShort" -JobTemp_DP "#JobRoot_DP#\01-JobTemp" -RfProg_DPNE "C:\Program Files\Siemens\NX12\nxbin\part_utility.exe" -ShellMaxDurationSEC "-1" -JobData1ToProcessDoPrint -JobData2ResultsDoPrint -ResultClassification_DPNE "#JobRoot_DP#\Resources\NxPartUtilNativSylog_ResClRules.xml" -Verbose -PauseOnEnd -Test

#New: 3.1491;19.02.2020;J.Fes 10 AP from  D:\Daten_CAD_02
-Action "RefileNative_2016_02" -SubAction "PartByPart" -RfParam "''-managed_mode=no -co -convert_mcs -convert_line_widths -regen_lw''" -JobRoot_DP "V:\CustomersDataL\SuS\2020-02-19-ExampleData\Daten_CAD_02_NX12PartUtilNativ3_APmcs_M_00065_CustomerNameShort" -JobTemp_DP "#JobRoot_DP#\01-JobTemp" -ConvertMcs_Archiv_DP "D:\Daten_CAD_02.CustomMcsLog" -RfProg_DPNE "C:\Program Files\Siemens\NX12\nxbin\part_utility.exe" -ShellMaxDurationSEC "-1" -JobData1ToProcessDoPrint -JobData2ResultsDoPrint -ResultClassification_DPNE "#JobRoot_DP#\Resources\NxPartUtilNativSylog_ResClRules.xml" -Verbose -PauseOnEnd -Test

#New: 3.1491;20.02.2020;J.Fes 1 Ap from   D:\Daten_CAD_02 has ISSUE' [nRfLogMcs:CHK:'05:!!- All constraints deleted -!!' #WRN.n:1 #MCS.n:1}
-Action "RefileNative_2016_02" -SubAction "PartByPart" -RfParam "''-managed_mode=no -co -convert_mcs -convert_line_widths -regen_lw''" -JobRoot_DP "V:\CustomersDataL\SuS\2020-02-20-ExampleData\Daten_CAD_02_NX12PartUtilNativ3_APmcs_M_00149_CustomerNameShort" -JobTemp_DP "#JobRoot_DP#\01-JobTemp" -ConvertMcs_Archiv_DP "D:\Daten_CAD_02.CustomMcsLog" -RfProg_DPNE "C:\Program Files\Siemens\NX12\nxbin\part_utility.exe" -ShellMaxDurationSEC "-1" -JobData1ToProcessDoPrint -JobData2ResultsDoPrint -ResultClassification_DPNE "#JobRoot_DP#\Resources\NxPartUtilNativSylog_ResClRules.xml" -Verbose -PauseOnEnd -Test

#Doc: 17.02.2020 !!!! ### Importand -RfParam "''-para1 -para2''" ### !!!! -test schaltet erzeugung aus !! 

#New: 3.1601;02.01.2022;J.Fes
-Action "RefileNative_2016_02" 
-SubAction "PartByPart" 
-RfParam "''-managed_mode=no -co -convert_mcs -convert_line_widths -regen_lw''" 
-JobRoot_DP "V:\CustomersDataL\SuS\2020-02-20-ExampleData\Daten_CAD_02_NX12PartUtilNativ3_APmcs_M_00149_CustomerNameShort" 
-JobTemp_DP "#JobRoot_DP#\01-JobTemp" 
-ConvertMcs_Archiv_DP "D:\Daten_CAD_02.CustomMcsLog" 
-RfProg_DPNE "C:\Program Files\Siemens\NX12\nxbin\part_utility.exe" 
-ShellMaxDurationSEC "-1" 
-JobData1ToProcessDoPrint 
-JobData2ResultsDoPrint 
-ResultClassification_DPNE "#JobRoot_DP#\Resources\NxPartUtilNativSylog_ResClRules.xml" 
-xPartFileBackUpAndCopyBackToOriginFileLocation
-xPartFileBackUpAndCopyBackToOriginFileLocation_DP "V:\CustomersDataL\SuS\NXPrtBackup"
-Verbose -PauseOnEnd -Test -pause




--------------------------------------------------------------------------------------------------------------------------------------------------------------------
